WebNov 12, 2012 · IRC 2411.1.1 CSST. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the electrical service grounding electrode system at the point where the gas service enters the building. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. WebWhile FlashShield CSST shares many of the same fitting assembly and installation guidelines as our standard CSST, there are a few important differences. This bulletin is intended as a quick summary of those differences, and is not intended to replace our official installation guide. FlashShield CSST Fittings and Installation Guide
Concerns About CSST Gas Lines - Grounded in Reality?
WebAll gas piping systems containing at least one run of CSST must be bonded per the National Fuel Gas code and the manufacturer's written instructions to achieve safety standards. … Webaccessible, and the bond is in addition to any bonding requirements as specified by local codes. • Attachment between the CSST gas piping system and the bonding clamp must … how did shane become a walker
No. 08-04 Grounding of Gas Piping Systems and …
Webfailure to bond the system according to the manufacturer’s instructions may or may not be a violation of the National Fuel Gas Code (NFGC), the National ... A permanent electrical connection to the earth must be made by bonding the CSST to the grounding system through the use of a bonding clamp and wire in accordance with the National ... WebThe NEC prescribes the minimum bonding conductor size based on the ampacity of the over current device serving the appliance, which could be as small as a #12 AWG conductor. The manufacturer’s installation instructions for CSST and the International Fuel Gas Code require that when CSST is used the gas pipe be bonded with a minimum #6 … WebThe bonding conductor must not be smaller than a 6 AWG copper wire or the equivalent size if made of aluminum. The means for attaching the bonding conductor to the grounding electrode system must be in accordance with NFPA 70. The bonding conductor must be not longer than 75 feet (22,860 MM). The location of the bonding clamp on the gas piping ... how many speeding points do i have